<?xml version="1.0" encoding="UTF-8"?>
<zabbix_export><version>5.0</version><date>2021-11-21T21:23:42Z</date><groups><group><name>Templates</name></group></groups><templates><template><template>Dell iDrac SNMPV2</template><name>Dell idrac</name><description>## Overview

这是[https://share.zabbix.com/network\_devices/cat-dell-sonicwall/dell-idrac](network_devices/cat-dell-sonicwall/dell-idrac)的中文化版本，同时进行了修正以支持zabbix3.0，感谢原作者



</description><groups><group><name>Templates</name></group></groups><applications><application><name>Disks / Storage</name></application><application><name>Fans</name></application><application><name>Memory</name></application><application><name>Network Cards</name></application><application><name>Power</name></application><application><name>System Info</name></application><application><name>Temperatures</name></application><application><name>Voltages</name></application></applications><items><item><name>BIOS 生产日期</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.300.50.1.7.1.1</snmp_oid><key>BiosDate</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>System Info</name></application></applications></item><item><name>BIOS 版本</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.300.50.1.8.1.1</snmp_oid><key>BiosVersion</key><delay>86400</delay><trends>0</trends><value_type>CHAR</value_type><applications><application><name>System Info</name></application></applications></item><item><name>CMOS 电池状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.600.50.1.5.1.1</snmp_oid><key>CMOSBatteryStatus</key><delay>60</delay><applications><application><name>System Info</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><triggers><trigger><expression>{last(0)}&lt;&gt;3</expression><name>物理机 {HOST.NAME} CMOS 电池异常</name><priority>WARNING</priority></trigger></triggers></item><item><name>系统状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.2.2.1.0</snmp_oid><key>GlobalSystemStatus</key><delay>60</delay><history>7d</history><applications><application><name>System Info</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><triggers><trigger><expression>{nodata(300)}</expression><name>物理机 {HOST.NAME} iDrac 5分钟无数据</name><priority>WARNING</priority></trigger><trigger><expression>{last()}&gt;4</expression><name>物理机 {HOST.NAME} 发生严重错误</name><priority>DISASTER</priority></trigger></triggers></item><item><name>iDRAC 访问地址</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.2.1.1.7.0</snmp_oid><key>idrac_acessurl</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><inventory_link>URL_A</inventory_link><applications><application><name>System Info</name></application></applications></item><item><name>标记号</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.2.1.1.11.0</snmp_oid><key>idrac_assettag</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><inventory_link>ASSET_TAG</inventory_link><applications><application><name>System Info</name></application></applications></item><item><name>系统服务号</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.1.3.3.0</snmp_oid><key>idrac_esc</key><delay>86400</delay><trends>0</trends><value_type>CHAR</value_type><applications><application><name>System Info</name></application></applications></item><item><name>iDRAC 固件版本</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.2.1.1.5.0</snmp_oid><key>idrac_firmwareversion</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>System Info</name></application></applications></item><item><name>型号</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.1.3.12.0</snmp_oid><key>idrac_SystemModel</key><delay>86400</delay><trends>0</trends><value_type>CHAR</value_type><inventory_link>MODEL</inventory_link><applications><application><name>System Info</name></application></applications></item><item><name>iDRAC 版本</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.2.1.1.2.0</snmp_oid><key>idrac_version</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>System Info</name></application></applications></item><item><name>电源无功功率</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.600.60.1.15.1.1</snmp_oid><key>PowerUsageMinIdle</key><delay>120</delay><units>W</units><applications><application><name>Power</name></application></applications></item><item><name>电源传感器状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.600.60.1.5.1.1</snmp_oid><key>PowerUsageSensorStatus</key><delay>120</delay><history>7d</history><trends>0</trends><applications><application><name>Power</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap></item><item><name>RAID 控制器固件版本</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8.1</snmp_oid><key>RAIDControllerFirmware</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Disks / Storage</name></application></applications></item><item><name>RAID 控制器名称</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.2.1</snmp_oid><key>RAIDControllerName</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Disks / Storage</name></application></applications></item><item><name>RAID 控制器状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.37.1</snmp_oid><key>RAIDControllerStatus</key><delay>60</delay><history>7d</history><trends>0</trends><applications><application><name>Disks / Storage</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><triggers><trigger><expression>{last(0)}&lt;&gt;3</expression><name>物理机 {HOST.NAME} raid控制器错误</name><priority>HIGH</priority></trigger></triggers></item><item><name>BIOS 状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.300.50.1.5.1.1</snmp_oid><key>SystemBiosStatus</key><delay>60</delay><history>7d</history><trends>0</trends><applications><application><name>System Info</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap></item><item><name>电压状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.200.10.1.12.1</snmp_oid><key>VoltageStatusCombined</key><delay>120</delay><history>7d</history><trends>0</trends><applications><application><name>Voltages</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><triggers><trigger><expression>{last(0)}&lt;&gt;3</expression><name>物理机 {HOST.NAME} 电压异常</name><priority>HIGH</priority></trigger></triggers></item></items><discovery_rules><discovery_rule><name>Disk Enumeration</name><type>SNMP_AGENT</type><snmp_oid>discovery[{#DISKNAME}, 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2]</snmp_oid><key>DiskEnumeration</key><delay>7200</delay><item_prototypes><item_prototype><name>磁盘 {#DISKNAME} : 生产日</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.32.{#SNMPINDEX}</snmp_oid><key>DiskManufactureDay.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><applications><application><name>Disks / Storage</name></application></applications></item_prototype><item_prototype><name>磁盘 {#SNMPINDEX} : 制造商</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.3.{#SNMPINDEX}</snmp_oid><key>DiskManufacturer.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Disks / Storage</name></application></applications></item_prototype><item_prototype><name>磁盘 {#SNMPINDEX} : 生产周</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.33.{#SNMPINDEX}</snmp_oid><key>DiskManufactureWeek.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><applications><application><name>Disks / Storage</name></application></applications></item_prototype><item_prototype><name>磁盘 {#DISKNAME} : 生产年份</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.34.{#SNMPINDEX}</snmp_oid><key>DiskManufactureYear.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><applications><application><name>Disks / Storage</name></application></applications></item_prototype><item_prototype><name>磁盘 {#DISKNAME} : 型号</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6.{#SNMPINDEX}</snmp_oid><key>DiskModel.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Disks / Storage</name></application></applications></item_prototype><item_prototype><name>磁盘 {#DISKNAME} : 名称</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.55.{#SNMPINDEX}</snmp_oid><key>DiskName.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Disks / Storage</name></application></applications></item_prototype><item_prototype><name>磁盘 {#DISKNAME} : 序列号</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7.{#SNMPINDEX}</snmp_oid><key>DiskSerialNo.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Disks / Storage</name></application></applications></item_prototype><item_prototype><name>磁盘 {#DISKNAME} : 磁盘大小</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.11.{#SNMPINDEX}</snmp_oid><key>DiskSize.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><units>B</units><applications><application><name>Disks / Storage</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>1048576</params></step></preprocessing></item_prototype><item_prototype><name>磁盘 {#DISKNAME} : 状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.4.{#SNMPINDEX}</snmp_oid><key>DiskState.[{#SNMPINDEX}]</key><delay>300</delay><history>7d</history><applications><application><name>Disks / Storage</name></application></applications><valuemap><name>DellDracDiskState</name></valuemap></item_prototype></item_prototypes></discovery_rule><discovery_rule><name>Fan Enumeration</name><type>SNMP_AGENT</type><snmp_oid>discovery[{#FAN}, 1.3.6.1.4.1.674.10892.5.4.700.12.1.8.1]</snmp_oid><key>FanEnumeration</key><delay>7200</delay><item_prototypes><item_prototype><name>风扇 {#FAN} 转速</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.700.12.1.6.1.{#SNMPINDEX}</snmp_oid><key>FanSpeed.[{#SNMPINDEX}]</key><delay>120</delay><units>rpm</units><applications><application><name>Fans</name></application></applications></item_prototype><item_prototype><name>风扇 {#FAN} 状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.700.12.1.5.1.{#SNMPINDEX}</snmp_oid><key>FanStatus.[{#SNMPINDEX}]</key><delay>120</delay><history>7d</history><applications><application><name>Fans</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><trigger_prototypes><trigger_prototype><expression>{last(0)}&lt;&gt;3</expression><name>物理机 {HOSTNAME} 风扇 {#FAN} 异常</name><priority>AVERAGE</priority></trigger_prototype></trigger_prototypes></item_prototype></item_prototypes><graph_prototypes><graph_prototype><name>FAN {#FAN}</name><graph_items><graph_item><color>C80000</color><item><host>Dell iDrac SNMPV2</host><key>FanSpeed.[{#SNMPINDEX}]</key></item></graph_item></graph_items></graph_prototype></graph_prototypes></discovery_rule><discovery_rule><name>Memory Enumeration</name><type>SNMP_AGENT</type><snmp_oid>discovery[{#MEM},1.3.6.1.4.1.674.10892.5.4.1100.50.1.8.1]</snmp_oid><key>MemoryEnum</key><delay>43200;50/1-7,00:00-24:00</delay><item_prototypes><item_prototype><name>内存 {#MEM} 制造商</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.50.1.21.1.{#SNMPINDEX}</snmp_oid><key>MemManufacturer[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Memory</name></application></applications></item_prototype><item_prototype><name>内存 {#MEM} 序列号</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.50.1.23.1.{#SNMPINDEX}</snmp_oid><key>MemSerialNo.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Memory</name></application></applications></item_prototype><item_prototype><name>内存 {#MEM} 大小</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.50.1.14.1.{#SNMPINDEX}</snmp_oid><key>MemSize.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><units>B</units><applications><application><name>Memory</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>1024</params></step></preprocessing></item_prototype><item_prototype><name>内存 {#MEM} 速度</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.50.1.15.1.{#SNMPINDEX}</snmp_oid><key>MemSpeed.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><units>MHz</units><applications><application><name>Memory</name></application></applications></item_prototype><item_prototype><name>内存 {#MEM} 状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.50.1.5.1.{#SNMPINDEX}</snmp_oid><key>MemStatus.[{#SNMPINDEX}]</key><delay>60</delay><history>7d</history><applications><application><name>Memory</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><trigger_prototypes><trigger_prototype><expression>{last(0)}&lt;&gt;3</expression><name>物理机{HOST.NAME} 内存 {#MEM} 错误</name><priority>HIGH</priority></trigger_prototype></trigger_prototypes></item_prototype></item_prototypes></discovery_rule><discovery_rule><name>Network Enumeration</name><type>SNMP_AGENT</type><snmp_oid>discovery[{#NETIF},1.3.6.1.4.1.674.10892.5.4.1100.90.1.2.1]</snmp_oid><key>NetworkEnum</key><delay>7200</delay><item_prototypes><item_prototype><name>网卡 {#NETIF} : 连接状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.90.1.4.1.{#SNMPINDEX}</snmp_oid><key>NetConnStatus.[{#SNMPINDEX}]</key><delay>120</delay><history>7d</history><applications><application><name>Network Cards</name></application></applications><valuemap><name>Dell iDRAC Network Device Connection Status</name></valuemap><trigger_prototypes><trigger_prototype><expression>{diff(0)}=1</expression><name>物理机 {#HOSTNAME}  网卡 {#NETIF} 状态变化</name><priority>WARNING</priority></trigger_prototype></trigger_prototypes></item_prototype><item_prototype><name>网卡 {#NETIF} : 名称</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.90.1.6.1.{#SNMPINDEX}</snmp_oid><key>NetName.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Network Cards</name></application></applications></item_prototype><item_prototype><name>网卡 {#NETIF} : 槽位</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.90.1.30.1.{#SNMPINDEX}</snmp_oid><key>NetSlot.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Network Cards</name></application></applications></item_prototype><item_prototype><name>网卡 {#NETIF} : 状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.90.1.3.1.{#SNMPINDEX}</snmp_oid><key>NetStatus.[{#SNMPINDEX}]</key><delay>60</delay><history>7d</history><applications><application><name>Network Cards</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><trigger_prototypes><trigger_prototype><expression>{last(0)}&lt;&gt;3</expression><name>物理机{HOST.NAME}  网卡 {#NETIF} 状态异常</name><priority>HIGH</priority></trigger_prototype></trigger_prototypes></item_prototype></item_prototypes></discovery_rule><discovery_rule><name>Power Supply Enumeration</name><type>SNMP_AGENT</type><snmp_oid>discovery[{#POWER},1.3.6.1.4.1.674.10892.5.4.600.12.1.1.1]</snmp_oid><key>PowerSupplies</key><delay>7200</delay><item_prototypes><item_prototype><name>电源 {#POWER} 输入电压</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.600.12.1.9.1.{#SNMPINDEX}</snmp_oid><key>PowerSupplyInputVoltage.[{#SNMPINDEX}]</key><delay>300</delay><history>7d</history><value_type>FLOAT</value_type><units>V</units><applications><application><name>Power</name></application></applications></item_prototype><item_prototype><name>电源 {#POWER} 最大功率</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.600.12.1.6.1.{#SNMPINDEX}</snmp_oid><key>PowerSupplyMaxPower.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>FLOAT</value_type><units>W</units><applications><application><name>Power</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item_prototype><item_prototype><name>电源 {#POWER} 传感器状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.600.12.1.11.1.{#SNMPINDEX}</snmp_oid><key>PowerSupplySensorState.[{#SNMPINDEX}]</key><delay>300</delay><history>7d</history><applications><application><name>Power</name></application></applications><valuemap><name>Dell_PSU_SensorState</name></valuemap><trigger_prototypes><trigger_prototype><expression>{last(0)}&lt;&gt;1</expression><name>物理机 {HOST.NAME} 电源 {#POWER} 状态异常</name><priority>HIGH</priority></trigger_prototype></trigger_prototypes></item_prototype><item_prototype><name>电源 {#POWER} 状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.600.12.1.4.1.{#SNMPINDEX}</snmp_oid><key>PowerSupplyStateSettings.[{#SNMPINDEX}]</key><delay>120</delay><history>7d</history><applications><application><name>Power</name></application></applications><valuemap><name>Dell PSU State Settings</name></valuemap></item_prototype></item_prototypes></discovery_rule><discovery_rule><name>Processor Enumeration</name><type>SNMP_AGENT</type><snmp_oid>discovery[{#CPU},1.3.6.1.4.1.674.10892.5.4.1100.32.1.7.1]</snmp_oid><key>ProcEnum</key><delay>43200</delay><item_prototypes><item_prototype><name>处理器 {#SNMPINDEX} 状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.1100.32.1.5.1.{#SNMPINDEX}</snmp_oid><key>ProcStatus.[{#SNMPINDEX}]</key><delay>300</delay><history>7d</history><trends>0</trends><applications><application><name>System Info</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><trigger_prototypes><trigger_prototype><expression>({last(0)}&lt;&gt;3 and {last(0)}&lt;&gt;2) or ({last(86400)}&lt;&gt;2 and {last(0)}=2)</expression><name>物理机 {HOST.NAME} 处理器 {#SNMPINDEX} 状态异常</name><priority>HIGH</priority></trigger_prototype></trigger_prototypes></item_prototype></item_prototypes></discovery_rule><discovery_rule><name>Temperature Enumeration</name><type>SNMP_AGENT</type><snmp_oid>discovery[{#TEMP},1.3.6.1.4.1.674.10892.5.4.700.20.1.8.1]</snmp_oid><key>TempEnum</key><delay>7200</delay><item_prototypes><item_prototype><name>温度传感器 {#TEMP} 状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.700.20.1.5.1.{#SNMPINDEX}</snmp_oid><key>TempStatus.[{#SNMPINDEX}]</key><delay>300</delay><history>7d</history><trends>0</trends><applications><application><name>Temperatures</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><trigger_prototypes><trigger_prototype><expression>{last(0)}&lt;&gt;3</expression><name>物理机 {HOST.NAME} 温度传感器 {#TEMP} 状态异常</name><priority>HIGH</priority></trigger_prototype></trigger_prototypes></item_prototype><item_prototype><name>温度传感器 {#TEMP} 温度值</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.700.20.1.6.1.{#SNMPINDEX}</snmp_oid><key>TempValue.[{#SNMPINDEX}]</key><delay>60</delay><history>7d</history><value_type>FLOAT</value_type><units>C</units><applications><application><name>Temperatures</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item_prototype></item_prototypes><graph_prototypes><graph_prototype><name>Temperature on sensor {#TEMP}</name><graph_items><graph_item><color>C80000</color><calc_fnc>ALL</calc_fnc><item><host>Dell iDrac SNMPV2</host><key>TempValue.[{#SNMPINDEX}]</key></item></graph_item></graph_items></graph_prototype></graph_prototypes></discovery_rule><discovery_rule><name>Voltage Table Enumeration</name><type>SNMP_AGENT</type><snmp_oid>discovery[{#VOLTAGE}, 1.3.6.1.4.1.674.10892.5.4.600.20.1.8.1]</snmp_oid><key>VoltageTable</key><delay>7200</delay><item_prototypes><item_prototype><name>组件 {#VOLTAGE} : 电压状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.4.600.20.1.5.1.{#SNMPINDEX}</snmp_oid><key>VoltageStatus.[{#SNMPINDEX}]</key><delay>120</delay><history>7d</history><trends>0</trends><applications><application><name>Voltages</name></application></applications><valuemap><name>Dell Open Manage System Status</name></valuemap><trigger_prototypes><trigger_prototype><expression>{last(0)}&lt;&gt;3</expression><name>物理机 {HOST.NAME} 电压组件 {#VOLTAGE} 异常</name><priority>AVERAGE</priority></trigger_prototype></trigger_prototypes></item_prototype></item_prototypes></discovery_rule><discovery_rule><name>Disk Volume Enumeration</name><type>SNMP_AGENT</type><snmp_oid>discovery[{#VOLNAME},1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.1]</snmp_oid><key>VolumeEnum</key><delay>7200</delay><item_prototypes><item_prototype><name>磁盘卷 {#VOLNAME} : 状态</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.4.{#SNMPINDEX}</snmp_oid><key>VolumeDiskState.[{#SNMPINDEX}]</key><delay>90</delay><history>7d</history><applications><application><name>Disks / Storage</name></application></applications><valuemap><name>DellRaidVolumeState</name></valuemap><trigger_prototypes><trigger_prototype><expression>{last(0)}&lt;&gt;2</expression><name>物理机{HOST.NAME} 磁盘卷 {#VOLNAME} 错误</name><priority>HIGH</priority></trigger_prototype></trigger_prototypes></item_prototype><item_prototype><name>磁盘卷 {#SNMPINDEX} : 名称</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.36.{#SNMPINDEX}</snmp_oid><key>VolumeName.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><value_type>CHAR</value_type><applications><application><name>Disks / Storage</name></application></applications></item_prototype><item_prototype><name>磁盘卷 {#SNMPINDEX} : 大小</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.6.{#SNMPINDEX}</snmp_oid><key>VolumeSize.[{#SNMPINDEX}]</key><delay>86400</delay><history>7d</history><trends>0</trends><units>B</units><applications><application><name>Disks / Storage</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>1048576</params></step></preprocessing></item_prototype><item_prototype><name>磁盘卷 {#SNMPINDEX} : Raid级别</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13.{#SNMPINDEX}</snmp_oid><key>VolumeState.[{#SNMPINDEX}]</key><delay>3600</delay><history>7d</history><trends>0</trends><applications><application><name>Disks / Storage</name></application></applications><valuemap><name>DellRaidLevel</name></valuemap></item_prototype></item_prototypes></discovery_rule></discovery_rules><macros><macro><macro>{$SNMP_COMMUNITY}</macro><value>public</value></macro></macros></template></templates><value_maps><value_map><name>DellDracDiskState</name><mappings><mapping><value>1</value><newvalue>Unknown</newvalue></mapping><mapping><value>2</value><newvalue>Ready</newvalue></mapping><mapping><value>3</value><newvalue>Online</newvalue></mapping><mapping><value>4</value><newvalue>Foreign</newvalue></mapping><mapping><value>5</value><newvalue>Offline</newvalue></mapping><mapping><value>6</value><newvalue>Blocked</newvalue></mapping><mapping><value>7</value><newvalue>Failed</newvalue></mapping><mapping><value>8</value><newvalue>Non-RAID</newvalue></mapping><mapping><value>9</value><newvalue>Removed</newvalue></mapping></mappings></value_map><value_map><name>Dell iDRAC Network Device Connection Status</name><mappings><mapping><value>1</value><newvalue>Up</newvalue></mapping><mapping><value>2</value><newvalue>Down</newvalue></mapping><mapping><value>3</value><newvalue>driverBad</newvalue></mapping><mapping><value>4</value><newvalue>driverDisabled</newvalue></mapping><mapping><value>10</value><newvalue>hardwareInitalizing</newvalue></mapping><mapping><value>11</value><newvalue>hardwareResetting</newvalue></mapping><mapping><value>12</value><newvalue>hardwareClosing</newvalue></mapping><mapping><value>13</value><newvalue>hardwareNotReady</newvalue></mapping></mappings></value_map><value_map><name>Dell Open Manage System Status</name><mappings><mapping><value>1</value><newvalue>Other</newvalue></mapping><mapping><value>2</value><newvalue>Unknown</newvalue></mapping><mapping><value>3</value><newvalue>OK</newvalue></mapping><mapping><value>4</value><newvalue>NonCritical</newvalue></mapping><mapping><value>5</value><newvalue>Critical</newvalue></mapping><mapping><value>6</value><newvalue>NonRecoverable</newvalue></mapping></mappings></value_map><value_map><name>Dell PSU State Settings</name><mappings><mapping><value>1</value><newvalue>Unknown</newvalue></mapping><mapping><value>2</value><newvalue>Online (state disabled)</newvalue></mapping><mapping><value>4</value><newvalue>not Ready</newvalue></mapping><mapping><value>8</value><newvalue>Fan Failure</newvalue></mapping><mapping><value>10</value><newvalue>Online and Fan Failure</newvalue></mapping><mapping><value>16</value><newvalue>on</newvalue></mapping><mapping><value>242</value><newvalue>Online and OK</newvalue></mapping></mappings></value_map><value_map><name>DellRaidLevel</name><mappings><mapping><value>1</value><newvalue>Unknown</newvalue></mapping><mapping><value>2</value><newvalue>RAID-0</newvalue></mapping><mapping><value>3</value><newvalue>RAID-1</newvalue></mapping><mapping><value>4</value><newvalue>RAID-5</newvalue></mapping><mapping><value>5</value><newvalue>RAID-6</newvalue></mapping><mapping><value>6</value><newvalue>RAID-10</newvalue></mapping><mapping><value>7</value><newvalue>RAID-50</newvalue></mapping><mapping><value>8</value><newvalue>RAID-60</newvalue></mapping><mapping><value>9</value><newvalue>Concatenated RAID 1</newvalue></mapping><mapping><value>10</value><newvalue>Concatenated RAID 5</newvalue></mapping></mappings></value_map><value_map><name>DellRaidVolumeState</name><mappings><mapping><value>1</value><newvalue>Unknown</newvalue></mapping><mapping><value>2</value><newvalue>Online</newvalue></mapping><mapping><value>3</value><newvalue>Failed</newvalue></mapping><mapping><value>4</value><newvalue>Degraded</newvalue></mapping></mappings></value_map><value_map><name>Dell_PSU_SensorState</name><mappings><mapping><value>1</value><newvalue>Presence Detected</newvalue></mapping><mapping><value>2</value><newvalue>PS Failure</newvalue></mapping><mapping><value>4</value><newvalue>Predictuve Failure</newvalue></mapping><mapping><value>8</value><newvalue>PS AC lost</newvalue></mapping><mapping><value>16</value><newvalue>AC lost or out of range</newvalue></mapping><mapping><value>32</value><newvalue>AC out of range but still present</newvalue></mapping><mapping><value>64</value><newvalue>Configuration Error</newvalue></mapping></mappings></value_map></value_maps></zabbix_export>
