<?xml version="1.0" encoding="UTF-8"?>
<zabbix_export><version>5.0</version><date>2021-11-21T21:40:27Z</date><groups><group><name>Templates</name></group></groups><templates><template><template>SNMP APC InRow</template><name>SNMP APC InRow</name><groups><group><name>Templates</name></group></groups><applications><application><name>Information</name></application><application><name>Temperature</name></application></applications><items><item><name>UPS InRow Firmware Revision</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.1.5.0</snmp_oid><key>AirirscunitIdentFirmwareRevision</key><delay>1h</delay><trends>0</trends><value_type>CHAR</value_type><description>A character string identifying the unit firmware version.</description><inventory_link>SOFTWARE</inventory_link><applications><application><name>Information</name></application></applications></item><item><name>UPS InRow Hardware Revision</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.1.6.0</snmp_oid><key>AirirscunitIdentHardwareRevision</key><delay>1h</delay><trends>0</trends><value_type>CHAR</value_type><description>A character string identifying the unit controller hardware revision.</description><inventory_link>HARDWARE</inventory_link><applications><application><name>Information</name></application></applications></item><item><name>UPS InRow Location</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.1.2.0</snmp_oid><key>AirirscunitIdentLocation</key><delay>1h</delay><trends>0</trends><value_type>CHAR</value_type><description>A character string identifying the unit location.</description><inventory_link>LOCATION</inventory_link><applications><application><name>Information</name></application></applications></item><item><name>UPS InRow Manufacture Date</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.1.7.0</snmp_oid><key>AirirscunitIdentManufactureDate</key><delay>1h</delay><trends>0</trends><value_type>CHAR</value_type><description>A character string identifying the unit manufacture date.</description><applications><application><name>Information</name></application></applications></item><item><name>UPS InRow Model Number</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.1.3.0</snmp_oid><key>AirirscunitIdentModelNumber</key><delay>1h</delay><trends>0</trends><value_type>CHAR</value_type><description>A character string identifying the unit model number.</description><inventory_link>MODEL</inventory_link><applications><application><name>Information</name></application></applications></item><item><name>UPS InRow Name</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.1.1.0</snmp_oid><key>AirirscunitIdentName</key><delay>1h</delay><trends>0</trends><value_type>CHAR</value_type><description>A character string identifying the unit name.</description><inventory_link>NAME</inventory_link><applications><application><name>Information</name></application></applications></item><item><name>UPS InRow Serial Number</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.1.4.0</snmp_oid><key>AirirscunitIdentSerialNumber</key><delay>1h</delay><trends>0</trends><value_type>CHAR</value_type><description>A character string identifying the unit serial number.</description><inventory_link>SERIALNO_A</inventory_link><applications><application><name>Information</name></application></applications></item><item><name>UPS InRow Cond Inlet Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.2.31.0</snmp_oid><key>AirirscunitStatusCondInletTempMetric</key><delay>3m</delay><value_type>FLOAT</value_type><units>C</units><description>The unit condenser inlet air temperature in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item><item><name>UPS InRow Cond Outlet Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.2.29.0</snmp_oid><key>AirirscunitStatusCondOutletTempMetric</key><delay>3m</delay><value_type>FLOAT</value_type><units>C</units><description>The unit condenser outlet air temperature in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item><item><name>UPS InRow Rack Inlet Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.2.7.0</snmp_oid><key>AirirscunitStatusRackInletTemp</key><delay>3m</delay><value_type>FLOAT</value_type><units>C</units><description>The unit rack inlet temperature in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item><item><name>UPS InRow Return Air Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.2.11.0</snmp_oid><key>AirirscunitStatusReturnAirTempMetric</key><delay>3m</delay><value_type>FLOAT</value_type><units>C</units><description>The unit return air temperature in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item><item><name>UPS InRow Suction Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.2.13.0</snmp_oid><key>AirirscunitStatusSuctionTempMetric</key><delay>3m</delay><value_type>FLOAT</value_type><units>C</units><description>The unit suction temperature in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item><item><name>UPS InRow Superheat Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.2.15.0</snmp_oid><key>AirirscunitStatusSuperheatTempMetric</key><delay>3m</delay><value_type>FLOAT</value_type><units>C</units><description>The unit superheat temperature in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item><item><name>UPS InRow Supply Air Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.2.9.0</snmp_oid><key>AirirscunitStatusSupplyAirTempMetric</key><delay>3m</delay><value_type>FLOAT</value_type><units>C</units><description>The unit supply air temperature in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item><item><name>UPS InRow Thresholds Rack Inlet High Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.5.2.0</snmp_oid><key>AirirscunitThresholdsRackInletHighTempMetric</key><delay>1h</delay><value_type>FLOAT</value_type><units>C</units><description>Unit rack inlet air high temperature threshold in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item><item><name>UPS InRow Thresholds Return Air High Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.5.6.0</snmp_oid><key>AirirscunitThresholdsReturnAirHighTempMetric</key><delay>1h</delay><value_type>FLOAT</value_type><units>C</units><description>Unit return air high temperature threshold in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item><item><name>UPS InRow Thresholds Supply Air High Temp</name><type>SNMP_AGENT</type><snmp_oid>1.3.6.1.4.1.318.1.1.13.3.4.1.5.4.0</snmp_oid><key>AirirscunitThresholdsSupplyAirHighTempMetric</key><delay>1h</delay><value_type>FLOAT</value_type><units>C</units><description>Unit supply air high temperature threshold in tenths of degrees Celsius.</description><applications><application><name>Temperature</name></application></applications><preprocessing><step><type>MULTIPLIER</type><params>0.1</params></step></preprocessing></item></items></template></templates><triggers><trigger><expression>{SNMP APC InRow:AirirscunitStatusRackInletTemp.last()}&gt;{SNMP APC InRow:AirirscunitThresholdsRackInletHighTempMetric.last()}</expression><name>Rack Inlet temperature is too high on {HOST.NAME}</name><priority>HIGH</priority></trigger><trigger><expression>{SNMP APC InRow:AirirscunitStatusReturnAirTempMetric.last()}&gt;{SNMP APC InRow:AirirscunitThresholdsReturnAirHighTempMetric.last()}</expression><name>Return Air temperature is too high on {HOST.NAME}</name><priority>HIGH</priority></trigger><trigger><expression>{SNMP APC InRow:AirirscunitStatusSupplyAirTempMetric.last()}&gt;{SNMP APC InRow:AirirscunitThresholdsSupplyAirHighTempMetric.last()}</expression><name>Supply Air temperature is too high on {HOST.NAME}</name><priority>HIGH</priority></trigger></triggers><graphs><graph><name>Air temperature</name><graph_items><graph_item><color>1A7C11</color><item><host>SNMP APC InRow</host><key>AirirscunitStatusRackInletTemp</key></item></graph_item><graph_item><sortorder>1</sortorder><color>F63100</color><item><host>SNMP APC InRow</host><key>AirirscunitStatusReturnAirTempMetric</key></item></graph_item><graph_item><sortorder>2</sortorder><color>2774A4</color><item><host>SNMP APC InRow</host><key>AirirscunitStatusSupplyAirTempMetric</key></item></graph_item></graph_items></graph></graphs></zabbix_export>